When pressed the last set value
automatically functions. The led between the
button illuminates and the fan operates in the
3. speed.
If the indoor temperature the is higher than the
Set temperature air conditioner operates in the
cooling function. In cooling period condenser
immediately operates but compressor operates
After 20 seconds. While leaving the cooling
period, compressor stops operating immediately,
But Condenser stops after 20 seconds.
If the indoor temperature the is less than the
Set temperature air conditioners operates in the
heating function.
With the adjusted value The air conditioners
tolerance is +-1.5 for starting and leaving
operating for both heating and cooling
The auto function will not operate until the
motor operating signal reaches but fan and flap
Function will.
Heating : ON-OFF button
Outdoor Temperature: Can be monitored
for 3 seconds after pressing the button.
Interior Temperature: Can be monitored
for 3 seconds after pressing the button.
Fan Speed: When fan button is pressed, speed step of the
fan is increased. The fan speed is
Changed as 1-2-3-1-2 if the fan button is
pressed and the air conditioner is operating,
If the air conditioner is not operating changed
as 1-2-3-0-1-2. In the 1. speed the top led
Illuminates in the 2. speed the top and middle
leds illuminates in the 3. speed all 3, top
middle and bottom leds illuminates.
Flape Output: When the button is pressed, operates the relay of the flape continuously and lights the ledlamp. After repressing the button,
shuts the signal that operates the relay.
Up Arrow: Only has a
function if the air conditioner is operating.
The set temperature can be increased by KK 1ºC (SACU 0,5 ºC)
precision. The max. set temperature can only be
adjusted to 24C.
With the adjusted value The air conditioners
tolerance is +-1.5 for starting and leaving
operating for both heating and cooling
Down Arrow: Only has a
function if the air conditioner is operating. .
The set temperature can be decreased by KK 1ºC (SACU 0,5 ºC)
precision. The min. set temperature can only be
adjusted to 18C.
BLOWER SPEED CONTROL MODUL (SMK143)
Supply Voltage
24V
Max. Load current
22A
Function: Designed for blower. Starts the engine with soft-start and controls the angine rotation.
TERMOSTAT CONTROL UNIT (SA180)
Supply Voltage
V=9V-16V
TEMPERATURE SENSOR (STS802)
Used to measure the temperature in air condition control units.