Air Condition Control Units
 
  Technical Features:

● Voltage Range (10V-30V)

● Short circuit protection

● Output: 7 x 700mA

● ABS body

● Customer-specific diffirent panel options

● Diffirent LED colors available

 
       
When pressed the last set value automatically functions. The led between the button illuminates and the fan operates in the 3. speed.

If the indoor temperature the is higher than the Set temperature air conditioner operates in the cooling function. In cooling period condenser immediately operates but compressor operates
After 20 seconds. While leaving the cooling period, compressor stops operating immediately,
But Condenser stops after 20 seconds.

If the indoor temperature the is less than the Set temperature air conditioners operates in the heating function.

With the adjusted value The air conditioners tolerance is +-1.5 for starting and leaving operating for both heating and cooling

The auto function will not operate until the motor operating signal reaches but fan and flap
Function will.
   
Heating : ON-OFF button
   
Outdoor Temperature: Can be monitored for 3 seconds after pressing the button.
   
Interior Temperature: Can be monitored for 3 seconds after pressing the button.
   
Fan Speed: When fan button is pressed, speed step of the fan is increased. The fan speed is
Changed as 1-2-3-1-2 if the fan button is pressed and the air conditioner is operating,
If the air conditioner is not operating changed as 1-2-3-0-1-2. In the 1. speed the top led
Illuminates in the 2. speed the top and middle leds illuminates in the 3. speed all 3, top middle and bottom leds illuminates.
   
Flape Output: When the button is pressed, operates the relay of the flape continuously and lights the ledlamp. After repressing the button,
shuts the signal that operates the relay.
   
Up Arrow: Only has a function if the air conditioner is operating. The set temperature can be increased by KK 1ºC (SACU 0,5 ºC) precision. The max. set temperature can only be adjusted to 24C.
With the adjusted value The air conditioners tolerance is +-1.5 for starting and leaving operating for both heating and cooling
   
Down Arrow: Only has a function if the air conditioner is operating. . The set temperature can be decreased by KK 1ºC (SACU 0,5 ºC) precision. The min. set temperature can only be adjusted to 18C.
 
BLOWER SPEED CONTROL MODUL (SMK143)
   
Supply Voltage 24V
Max. Load current 22A
 
       
Function: Designed for blower. Starts the engine with soft-start and controls the angine rotation.
       
TERMOSTAT CONTROL UNIT (SA180)
       
Supply Voltage V=9V-16V
   
       
       
TEMPERATURE SENSOR (STS802)
       
Used to measure the temperature in air condition control units.    
       
KLAPE CONTROL UNIT(12V-24V)
       
Supply Voltage 9V – 32V
Stand by current (V=14V) max 35 mA
Max load current 1A
   
       
 